Complete environmental noise monitoring solution with Nor145.
Overview
The Nor145 environmental noise monitoring solution provides a versatile, standards-compliant platform for all aspects of environmental noise assessment according to ISO 1996 and regional regulations including Saudi PME (Presidency of Meteorology and Environment) requirements and UAE municipality noise ordinances. From short-term attended measurements at community boundaries to long-term unattended…
Key Features
- ISO 1996 compliant environmental noise measurement and assessment
- Built-in 4G LTE and WLAN for remote monitoring via NorCloud
- GPS/GNSS location tagging for geo-referenced, audit-ready documentation
- Configurable alarm thresholds with instant notification on exceedance
- Audio recording for source identification and complaint investigation
- Weather-triggered measurement control for wind speed exclusion
- Short-term attended and long-term unattended monitoring modes
- Real-time 1/1 and 1/3 octave spectrum analysis for source characterization
Applications
- Construction site boundary noise monitoring under permit conditions
- Industrial facility perimeter noise assessment for operating license compliance
- Community noise surveys and complaint investigation
- Traffic and road noise assessment per ISO 1996
- Airport and aviation noise monitoring programs
- Oil and gas facility boundary noise measurement
Technical Specifications
- Analyzer: Nor145
- Standards: IEC 61672-1 Class 1
- Logging: 100 ms to 1 hour intervals
- Connectivity: 4G LTE, WLAN
- Storage: 32 GB internal
Frequently Asked Questions
- How long can the Nor145 monitor unattended?
With external power supply and NorCloud connectivity, the Nor145 can monitor continuously and indefinitely with automatic data upload. On battery power alone, the instrument provides over 10 hours of operation. For extended deployments, the Nor1545 outdoor monitoring terminal provides weatherproof housing and permanent power. - Can weather data be recorded alongside noise measurements?
Yes, the Nor145 can integrate with external weather stations and include meteorological data (wind speed, direction, temperature, rainfall) in measurements. Weather-triggered pausing can automatically exclude measurements taken during high wind conditions from regulatory assessments. - Does the Nor145 meet Saudi PME noise monitoring requirements?
Yes, the Nor145 is a Class 1 instrument compliant with IEC 61672-1 and provides all the measurement parameters, logging capabilities, and documentation features required by Saudi PME environmental noise regulations and General Environmental Regulations and Rules for Implementation.
Application Guide
The Environmental Measurements with Nor145 belongs to the Norsonic Noise Monitoring range. See the Noise Monitoring application guide for system configuration, compatible accessories, and applicable measurement standards.
Related Norsonic Products
- Nor145 Sound Level Meter — Nor145 Class 1 sound level meter with 4.3" touchscreen, 4G LTE connectivity, GPS…
- Nor1545 Noise Monitoring Terminal — Nor1545 outdoor noise monitoring terminal with Class 1 sound level meter, weathe…
- NorCloud Noise Monitoring System — Cloud-based noise monitoring and fleet management platform for remote instrument…
Why Norsonic?
- Manufactured in Norway — decades of acoustic measurement heritage; all instruments designed and built in Norsonic AS, Lierskogen, Norway
- IEC 61672 Class 1 — highest accuracy class for professional and regulatory acoustic measurement
- International type approvals — PTB (Germany) and LNE (France); accepted by environmental authorities across the region
- 3-year manufacturer warranty — covers parts and labour; Norsonic Asia authorized service center support throughout the region
- Open data formats — .nox files work with NorReview and can be exported to CSV, Excel, and third-party analysis software
Calibration and Compliance
- All Norsonic instruments require periodic IEC 61672-3 calibration — Norsonic Asia provides factory-authorized calibration services with full DANAK-traceable certificates
- Calibration interval: 1 year for ISO 17025 accredited laboratories; 2 years for field instruments in non-accredited applications
- Field calibration check: use an IEC 60942 Class 1 sound calibrator (94 dB or 114 dB) before and after each measurement session
- Loaner instruments available during calibration to minimize project downtime — contact Norsonic Asia for loaner availability
Availability & Regional Support
Available from Norsonic Asia — the factory-authorized distributor for ASEAN, GCC, and South Asia. Instrument supply includes 3-year manufacturer warranty, factory-authorized calibration services, operator training, and after-sales technical support.
- Typical lead time: 3–6 weeks from order confirmation (ex-factory Norway)
- Countries served: Singapore, Malaysia, Thailand, Vietnam, Philippines, Indonesia, UAE, Saudi Arabia, Qatar, Kuwait, India, Bangladesh, Sri Lanka, and more
- Technical support: English and Arabic; response within 1 business day
← All Products | Download Datasheet | Find Local Distributor | Calibration Services