Building Acoustics with Nor150 (2ch)
Dual-channel building acoustics solution for ISO 16283 field testing.
Overview
The Nor150 dual-channel building acoustics solution delivers the most efficient and comprehensive approach to ISO 16283 field sound insulation testing. By measuring simultaneously in both the source and receiving rooms, the dual-channel Nor150 eliminates synchronization challenges and dramatically reduces on-site testing time compared to single-channel sequential methods. This efficiency advantage…
Key Features
- Simultaneous dual-channel source and receiver room measurements
- ISO 16283-1 airborne sound insulation testing with automated sequences
- ISO 16283-2 impact sound insulation testing with tapping machine and impact ball
- ISO 16283-3 facade sound insulation assessment capability
- Real-time DnT,w and L'nT,w calculation with spectrum adaptation terms
- Automated measurement sequences for consistent, standardized testing
- Low-frequency procedure per ISO 16283-1 Annex A for small rooms
- Compatible with Nor277 tapping machine, Nor279 impact ball, and Nor283 dodecahedron
Applications
- Residential apartment airborne and impact sound insulation testing
- Hotel and hospitality room acoustic isolation verification
- Commercial office partition sound insulation assessment
- Building facade sound insulation testing per ISO 16283-3
- Pre-completion acoustic testing for Vision 2030 mega-projects
- Saudi Building Code and UAE municipality acoustic compliance testing
Technical Specifications
- Analyzer: Nor150 (dual channel)
- Standards: ISO 16283-1, -2, -3
- Ratings: DnT,w, L'nT,w, Dls,2m,nT,w
- Sources: Nor277, Nor279, Nor283
Frequently Asked Questions
- Why use dual-channel for building acoustics?
Dual-channel operation enables simultaneous source and receiver room measurements, eliminating synchronization issues, reducing measurement time by up to 50%, and improving data consistency. This is especially valuable on large projects where hundreds of partitions must be tested within tight construction schedules. - What sound sources are required?
Airborne sound insulation testing requires the Nor283 dodecahedron loudspeaker with Nor280 or Nor282 power amplifier. Impact sound insulation testing requires the Nor277 tapping machine for standard impacts and optionally the Nor279 impact ball for low-frequency heavy impact assessment per ISO 16283-2 Annex B. - Does the system calculate single-number ratings automatically?
Yes, the Nor150 calculates standardized level differences (DnT,w) and normalized impact sound pressure levels (L'nT,w) with spectrum adaptation terms (C, Ctr) in real time, providing immediate pass/fail assessment against building code requirements on site.
Application Guide
The Building Acoustics with Nor150 (2ch) belongs to the Norsonic Building Acoustics range. See the Building Acoustics application guide for system configuration, compatible accessories, and applicable measurement standards.
Related Norsonic Products
- Nor150 Sound and Vibration Analyser — Nor150 dual-channel Class 1 sound and vibration analyser for building acoustics,…
- Nor277 Tapping Machine — Standard tapping machine for impact noise measurements in building acoustics tes…
- Nor850 Building Acoustics (ISO 16283) — Nor850 module for field building acoustics per ISO 16283.…
Why Norsonic?
- Manufactured in Norway — decades of acoustic measurement heritage; all instruments designed and built in Norsonic AS, Lierskogen, Norway
- IEC 61672 Class 1 — highest accuracy class for professional and regulatory acoustic measurement
- International type approvals — PTB (Germany) and LNE (France); accepted by environmental authorities across the region
- 3-year manufacturer warranty — covers parts and labour; Norsonic Asia authorized service center support throughout the region
- Open data formats — .nox files work with NorReview and can be exported to CSV, Excel, and third-party analysis software
Calibration and Compliance
- All Norsonic instruments require periodic IEC 61672-3 calibration — Norsonic Asia provides factory-authorized calibration services with full DANAK-traceable certificates
- Calibration interval: 1 year for ISO 17025 accredited laboratories; 2 years for field instruments in non-accredited applications
- Field calibration check: use an IEC 60942 Class 1 sound calibrator (94 dB or 114 dB) before and after each measurement session
- Loaner instruments available during calibration to minimize project downtime — contact Norsonic Asia for loaner availability
Availability & Regional Support
Available from Norsonic Asia — the factory-authorized distributor for ASEAN, GCC, and South Asia. Instrument supply includes 3-year manufacturer warranty, factory-authorized calibration services, operator training, and after-sales technical support.
- Typical lead time: 3–6 weeks from order confirmation (ex-factory Norway)
- Countries served: Singapore, Malaysia, Thailand, Vietnam, Philippines, Indonesia, UAE, Saudi Arabia, Qatar, Kuwait, India, Bangladesh, Sri Lanka, and more
- Technical support: English and Arabic; response within 1 business day