Material Testing

Nor1517 Tapping Machine

Standard tapping machine for floor impact sound testing according to ISO 10140 and ISO 16283-2.

Overview

The Nor1517 is a precision-engineered standard tapping machine designed for floor impact sound insulation measurements in both laboratory and field environments. Fully compliant with ISO 10140-5 and ISO 16283-2, it generates standardized impact sounds using five precision-machined cylindrical hammers, each weighing 500 g, falling from a controlled height of 40 mm at a rate of 10 impacts per second…

Key Features

  • Full compliance with ISO 10140-5 standard tapping machine requirements
  • Five precision-machined 500 g cylindrical hammers for standardized impact force
  • Precisely controlled 40 mm fall height and 10 Hz impact rate
  • Robust all-metal construction for reliable laboratory and field operation
  • Lightweight portable design (approx. 10 kg) for easy transport between test sites
  • Self-calibrating test function for verification of hammer parameters
  • Remote start capability for unmanned operation during measurements
  • Low background noise operation minimizing influence on measurement results

Applications

  • Floor impact sound insulation testing per ISO 10140-3 (laboratory) and ISO 16283-2 (field)
  • Hotel and hospitality floor construction acoustic verification for GCC mega-projects
  • Residential apartment building floor testing for Saudi Building Code compliance
  • Commercial office tower floor-ceiling assembly acoustic performance testing
  • NEOM, KAFD, and Dubai mega-project building acoustics quality assurance
  • Pre-completion acoustic testing and commissioning of new buildings

Technical Specifications

  • Hammers: 5 cylindrical hammers
  • Hammer mass: 500 g each
  • Fall height: 40 mm
  • Impact rate: 10 impacts per second (2 per hammer)
  • Standards: ISO 10140-5, ISO 16283-2, ASTM E492
  • Power supply: AC mains powered
  • Weight: Approx. 10 kg

Frequently Asked Questions

  • What is a tapping machine used for in floor impact sound testing?
    A tapping machine generates standardized impact sounds on a floor surface to measure the impact sound insulation performance of floor constructions. The Nor1517 produces precisely controlled impacts according to ISO 10140-5 requirements, enabling accurate determination of impact sound pressure levels (Ln and L'nT) used to calculate single-number ratings like Ln,w and L'nT,w.
  • Does the Nor1517 meet ISO 10140-5 tapping machine requirements?
    Yes, the Nor1517 is fully compliant with ISO 10140-5 requirements for standard tapping machines. It features five 500 g cylindrical hammers falling from a height of 40 mm at a rate of 10 impacts per second, meeting all mechanical parameters specified in the standard for both laboratory and field measurements.
  • Can the Nor1517 be used for field measurements according to ISO 16283-2?
    Yes, the Nor1517 is designed for both laboratory measurements per ISO 10140-3 and field measurements per ISO 16283-2. Its lightweight portable design (approx. 10 kg) makes it easy to transport to construction sites for in-situ floor impact sound testing.

Application Guide

The Nor1517 Tapping Machine belongs to the Norsonic Material Testing range. See the Material Testing application guide for system configuration, compatible accessories, and applicable measurement standards.

Related Norsonic Products

Why Norsonic?

  • Manufactured in Norway — decades of acoustic measurement heritage; all instruments designed and built in Norsonic AS, Lierskogen, Norway
  • IEC 61672 Class 1 — highest accuracy class for professional and regulatory acoustic measurement
  • International type approvals — PTB (Germany) and LNE (France); accepted by environmental authorities across the region
  • 3-year manufacturer warranty — covers parts and labour; Norsonic Asia authorized service center support throughout the region
  • Open data formats — .nox files work with NorReview and can be exported to CSV, Excel, and third-party analysis software

Calibration and Compliance

  • All Norsonic instruments require periodic IEC 61672-3 calibration — Norsonic Asia provides factory-authorized calibration services with full DANAK-traceable certificates
  • Calibration interval: 1 year for ISO 17025 accredited laboratories; 2 years for field instruments in non-accredited applications
  • Field calibration check: use an IEC 60942 Class 1 sound calibrator (94 dB or 114 dB) before and after each measurement session
  • Loaner instruments available during calibration to minimize project downtime — contact Norsonic Asia for loaner availability

Availability & Regional Support

Available from Norsonic Asia — the factory-authorized distributor for ASEAN, GCC, and South Asia. Instrument supply includes 3-year manufacturer warranty, factory-authorized calibration services, operator training, and after-sales technical support.

  • Typical lead time: 3–6 weeks from order confirmation (ex-factory Norway)
  • Countries served: Singapore, Malaysia, Thailand, Vietnam, Philippines, Indonesia, UAE, Saudi Arabia, Qatar, Kuwait, India, Bangladesh, Sri Lanka, and more
  • Technical support: English and Arabic; response within 1 business day

Request a Quote →

← All Products  |  Download Datasheet  |  Find Local Distributor  |  Calibration Services